The sibling-update path on prod failed with "Embedded PPSK not found by current passphrase" because the DB-stored x_passphrase on the unedited band was stale — earlier manual edits (pre-1.8.1) only touched one band, leaving the other band's row out of sync. When rotation then tried to use that stale passphrase to find the entry, no match. updateEmbeddedPpsk now takes an optional $name parameter and tries it first. PPSK names within a WLAN are unique, so name-matching survives any passphrase drift caused by historical out-of-band edits. Passphrase matching stays as a fallback for callers that don't have a name (none currently — both rotation and the manual modal pass it). v1.9.1. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>